18 Years Factory Ct Power Meter - JSY-MK-138 12 channel mutual inductance electric energy metering module – JIAN SI YAN

Description:


Product Detail

Product Tags

Related Video

Feedback (2)

"Sincerity, Innovation, Rigorousness, and Efficiency" is the persistent conception of our company for the long-term to develop together with customers for mutual reciprocity and mutual benefit for Multi Power Meter , Power Metering System , Three Phase Power Monitor , Together with our efforts, our products have won the trust of customers and been very salable both here and abroad.
18 Years Factory Ct Power Meter - JSY-MK-138 12 channel mutual inductance electric energy metering module – JIAN SI YAN Detail:

Description

Jsy-mk-138 12 way mutual inductance electric energy metering module can be widely used in energy-saving transformation, electric power, communication, railway, transportation, environmental protection, petrochemical, steel and other industries to monitor the current and power consumption of AC equipment.

Technical Parameter

1. Single phase AC input
1) Voltage range: 100V, 220V, 380V, etc.
2) Current range: 5A, 50a, 100A, etc; The model of external opening current transformer is optional.
3) Signal processing: special metering chip is adopted, and 24 bit AD is adopted.
4) Overload capacity: 1.2 times the range is sustainable; The instantaneous (<20ms) current is 5 times, the voltage is 1.2 times, and the range is not damaged.
5) Input impedance: voltage channel >1k Ω /v.

2. Communication interface
1) Interface type: 1-way RS-485 communication interface.
2) Communication protocol: MODBUS-RTU protocol.
3) Data format: software can set “n, 8,1″, “E, 8,1″, “O, 8,1″, “n, 8,2″.
4) Communication rate: the baud rate of RS-485 communication interface can be set to 9600, 19200, 38400bps; The baud rate defaults to 9600bps.

3. Test output data
Voltage, current, power, electric energy and other electrical parameters.

4. Measurement accuracy
Voltage, current and power: ± 1.0%; Active kwh is level 1.

5. Electrical isolation
RS-485 interface is isolated from AC power supply, voltage input and current input; Isolation withstand voltage 2000vac.

6. Power supply
1) Two power supply modes are selected: take power from the input AC phase C, and note that the voltage range is ac85~265; DC power supply can also be selected, and the input range is +9v~15v.
2) Typical power consumption: ≤ 1W.

7. Working environment
1) Working temperature: -20~+70 ℃; Storage temperature: -40~+85 ℃.
2) Relative humidity: 5~95%, no condensation (at 40 ℃).
3) Altitude: 0~3000 meters.
4) Environment: a place without explosion, corrosive gas and conductive dust, and without significant shaking, vibration and impact.

8. Temperature drift
≤100ppm/℃

9. Installation method
The distance between screw fixing and installation holes is 105*58.5mm

10. Product size
268*84*46mm


Product detail pictures:

18 Years Factory Ct Power Meter - JSY-MK-138 12 channel mutual inductance electric energy metering module – JIAN SI YAN detail pictures


Related Product Guide:

In an effort to provide you advantage and enlarge our business enterprise, we even have inspectors in QC Staff and assure you our greatest provider and item for 18 Years Factory Ct Power Meter - JSY-MK-138 12 channel mutual inductance electric energy metering module – JIAN SI YAN, The product will supply to all over the world, such as: French, Austria, Zimbabwe, Insisting on the high quality generation line management and customers expert assistance, we now have designed our resolution to offer our buyers using the to start with amount getting and just after services practical experience. Maintaining the prevailing friendly relations with our buyers, we however innovate our solution lists all of the time to satisfy the brand new demands and adhere to the most up-to-date development of the market in Malta. We are ready to face the worries and make the improve to understand all the possibilities in international trade.
  • This supplier stick to the principle of "Quality first, Honesty as base", it is absolutely to be trust.
    5 Stars By Elaine from Chicago - 2017.04.28 15:45
    It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Alva from Tanzania - 2017.08.18 18:38

    RELATED PRODUCTS