1.3.1 Single phase AC input
1) Voltage range: 100V, 220V, etc. optional.
2) Current range: 50A, 100A, 2 50A optional, external open current transformer model optional.
3) Signal processing: using special measurement chip, 24 -bit AD sampling.
4) Overload capacity: 1.2 times the range is sustainable; instantaneous (<20mS) current is 5 times, voltage is 1.2 times the range without damage.
5) Input impedance: voltage channel >1 kΩ/V; current channel ≤ 100mΩ.
1.3.2 Communication Interface
1) Communication standard 4G , CAT1 , supports LTE-TDD and LTE- FDD , supports China Mobile and China UnicomSIM cards.
2) Interface type: 2- way RS-485 interface.
3) Communication protocol: MODBUS-RTU protocol.
4) Data format: "n,8,1".
5) The baud rate of the RS-485 communication interface can be set to 1200, 2400, 4800, 9600Bps; the default baud rate is 9600Bps.
1.3.3 Measurement output data
Voltage, current, power, electric energy, power factor, frequency and other electrical parameters, please see the Mdobus data register list for details.
1.3.4 measurement accuracy
Voltage , current: ± 1.0 % ; active electricity level 1
1.3.5 isolation
RS-485 interface, isolated from power supply, voltage input, and current input.
isolation withstand voltage 2000VDC.
1.3.6 power supply
1) Optional 100V, 220V, voltage line 100V~220V.
2) When powered by AC220V, the peak voltage shall not exceed 265V; typical power consumption: ≤ 2W.
1.3.7 working environment
1) Working temperature: -20~+70℃ ; Storage temperature: -40~+85℃ .
2) Relative humidity: 5~95%, no condensation (at 40 ℃ ) .
3) Altitude: 0~3000 meters.
4) Environment: No explosive, corrosive gases and conductive dust, no significant shaking, vibration and impact.
1.3.8 Temperature drift: ≤100ppm/ ℃
1.3.9 Module size : 2P housing 3 5mm guide rail installation