The JSY-MK-339 three-phase voltage and current collector is a three-phase power quality detector developed by our company using microelectronics technology and dedicated large-scale integrated circuits, digital sampling processing technology and SMT technology and other advanced technologies with completely independent intellectual property rights. The technical performance of the detector is in full compliance with the relevant technical requirements of the 1 class three-phase active energy meter in the IEC 62053-21 national standard, and can directly and accurately measure the voltage, current, power, power factor, electricity and total electrical parameters in the three-phase AC power grid with a rated frequency of 50HZ or 60HZ. The collector has 1 channel RS485 communication interface, and a MODBUS-RTU communication protocol to facilitate connection with various AMR systems. It has the characteristics of good reliability, small size, light weight, beautiful appearance, and convenient installation.
JSY-MK-339 three-phase voltage and current collector can be widely used in energy-saving transformation, electric power, communication, railway, transportation, Environmental protection, petrochemical, steel and other industries, used to monitor the current and power consumption of AC equipment.
1. Three phase AC input
1) Voltage range: 100V, 220V, 380V, etc;
2) Current range: 50mA-80A
3) Signal processing: special measurement chip and 24 bit AD sampling;
4) Overload capacity: 1.2 times the range is sustainable; 5 times of instantaneous (<200ms) current and 2 times of voltage range without damage; Input impedance: voltage channel > 1 K Ω /v; Current channel ≤ 100m Ω.
2. Communication interface
1) Interface type: 1-way RS-485 communication interface.
2) Communication protocol: MODBUS-RTU protocol.
3) Data format: software can set "n, 8,1", "E, 8,1", "O, 8,1", "n, 8,2".
4) Communication rate: the baud rate of RS-485 communication interface can be set at 1200, 2400, 4800, 9600bps; The baud rate defaults to 9600bps.
3. Test output data
Voltage, current, power, electric energy and other electrical parameters.
4. Measurement accuracy
Voltage, current and power: ≤ 1.0%; Active energy measurement standard level 1.0
5. Power supply
Wide voltage power supply; 220VAC power supply; Typical power consumption: 50mA.
6. Working environment
1) Working temperature: -20~+60 ℃; Storage temperature: -40~+85 ℃.
2) Relative humidity: 5~95%, no condensation (at 40 ℃).
3) Altitude: 0~3000 meters.
4) Environment: a place without explosion, corrosive gas and conductive dust, and without significant shaking, vibration and impact.
7. Temperature drift
≤100ppm/℃
8. Installation method
Standard 4P guide rail installation